Bona Fide Engineering LLC offers maintenance services for instrumentation and automation. Our specialists have high qualifications and vast experience in working with various instrumentation and instrumentation equipment.
Today, we perform this type of work on the Taneco refinery
Types of ongoing work in the maintenance of instrumentation equipment:
No.
n / a
|
The name of the equipment | Periodicity |
1 | External inspection for mechanical damage. |
Once in 6
months
|
2 |
Removing dirt.
Check the tightness of all flanged and threaded connections. Verification
the status of the indicator (display) (if available).
|
Once in 6
months
|
3 | Check the reliability of electrical connections and grounding. |
Once in 6
months
|
4 |
Purging of impulse lines, condensate removal.
Testing the tightness of impulse line connections, elimination
loopholes.
|
Once in 6
months
|
5 |
Checking the tightness and reliability of fastening cable glands, voltages
power circuits.
|
Once in 6
months
|
6 |
Checking the status and labeling of the device, repairing them at
necessary.
|
Once in 6
months
|
7 | Inspection in accordance with the requirements for explosion-proof equipment. |
Once in 6
months
|
8 |
Checking the integrity of the corrugation (depending on the model).
Elimination of revealed remarks.
|
Once in 6
months
|
9 |
Registration of forms, maps of account of repair and maintenance of SI
and CA.
|
Once in 6
months
|