Automatic fire alarm (APS) (Fire alarm installation)


The APS includes subsystems:

  • Fire alarm.
  • Evacuation management.
  • Water, foam or gas fire extinguishing.
  • Control and access control (ACS)
  • Smoke removal and ventilation control.

The task of MTA:

  • Detection of any signs of ignition (gas, smoke or open fire) at the earliest stages.
  • Transfer of an alarm signal to the console or guard post.
  • Informing staff about the fire.
  •  Management of evacuation.
  • Automatic unlocking of all turnstiles, gates, doors for free evacuation.
  • Automatic return of elevators to the 1st floor and the opening of their doors.
  • Automatic activation of smoke and fire extinguishing systems.

The principle of the APS: Having detected signs of ignition at the earliest stage, APS:

  • Includes an alarm system (voice or light and sound) and evacuation control.
  • Simultaneously transmits control signals to all other subsystems: access control, smoke removal, elevator control, fire extinguishing and forced ventilation systems.

Characteristics of SAM types

  1. Ways of notification depending on the type of premises:
    • Sound (siren or toned spetssignal).
    • Speech (broadcasting previously recorded text).
    • Luminous: Blinking annunciators, signs "Exit".
  2. Separation of the object into warning zones.
  3. Feedback from the guard post.
  4. Centralized management of all building systems.

Purpose:
liquidation of a fire without damage to equipment at facilities with a large number of electrical equipment and high-tech equipment.

Operating principle:
immediately after automatic or manual start-up, the system fills the room with gas. By reducing the concentration of oxygen, this makes combustion impossible.

Destination:

the localization of smoke and gas, the release of evacuation routes from them, the preservation of human health and life.

 

Varieties

  • Gravitational. When an alarm is triggered, the pneumatic actuator opens the dome of an antiaircraft lamp mounted on the roof or in the windows. The lantern draws smoke.
  • Automatic. Draws on the fan by automatically turning on the fans

Organization of technical and administrative support Organization of quality control of work performance;

Mobilization (departure of personnel to an object with special clothing, PPE, special tools, accommodation, meals)

Stage 1 (preparatory work), the equipment is pre-installed (checked), the working documentation is reviewed, comments on equipment, correct installation, etc.

Stage 2 (offline setup) Provision of temporary power supply, preparation for the inclusion of systems: checking CO and software functioning, setting up logical and temporal relationships of alarm systems, protection , blocking and control; checking the correctness of the passage of signals;

Stage 3 (individual tests) constant voltage supply, system activation, software debugging, system operation check for individual testing of process equipment, correction hardware settings

Stage 4 (comprehensive setup) providing interconnections, adjusting and adjusting the characteristics and parameters of individual devices and functional groups, testing electrical equipment; systems of control, control, automation; systems PAZ, together with the technological equipment "under load" within 72 hours

Submission of a technical report (forms or passports for SI, lists of settings, settings, schematic diagrams with corrections, recommendations on the operation of systems) to the Customer

Transmission of power supply systems, automation into operation Signing of acceptance certificates

Closing financial documents